❄ Ice Machine Code Lookup
Home › Hoshizaki › DCM-60KE / DCM-120KE cubelet dispenser
Hoshizaki DCM-60KE / DCM-120KE cubelet dispenser · 18 codes

What does each Hoshizaki DCM-60KE/120KE dispenser code mean?

18 documented codes and fault signals for the Hoshizaki DCM-60KE / DCM-120KE cubelet dispenser, verified against service documentation. Find your code in the table below, click through to its section for the full explanation, causes, DIY steps, and when it needs a technician.

Which machines show these codes?

Which machines show this code: the DCM-60KE and DCM-120KE are Hoshizaki cubelet ice dispensers with a digital display — unlike the beep-only machines, these show actual codes, in two tiers that matter. Lowercase c-codes are cautions: the machine pauses or adjusts and usually resets itself automatically. Uppercase E-codes are interlock errors: the machine has stopped, dispensing is disabled, and most require a power-off/power-on reset after the cause is fixed. The tiers are connected — cautions escalate into errors when they repeat (two c8 low-production cautions become an E1 lockout; five c2 pressure cautions become an E4). So a caution code is the cheap moment to act: it's the machine telling you what the lockout will be.

Full code table

CodeWhat it meansLikely causeFirst check
E0Icemaking water leak (interlock error)A water leak in the icemaking circuit: reservoir, hoses, hose joints, the auger's mechanical seal, or the flush water valveWater on the floor or inside the cabinet
E1Low ice production (interlock error)A refrigerant gas leakCondenser and air filter
c1Low water cautionThe water supply valve closed or restrictedShut-off valve fully open
E2Float switch errorA float switch reporting an impossible state (tripped at both levels simultaneously)One power-off/power-on reset
c2Abnormal high-side pressure cautionThe condenser running hot: dirty coil, dirty filter, blocked clearanceAir filter
E3Gear motor error (protective circuit)The gear motor's thermal protector or overload opening under loadLeave the machine powered off for 30+ minutes
c3Abnormal low voltage cautionSupply voltage sagging below the setting for over a secondWhat else is on the same circuit
E4Abnormal high-side pressureFive high-pressure cautions (c2) within one hour of compressor runningClean the condenser and air filter
E5Gear motor drive element errorThe gear motor relay reading on when commanded off — miswiring or a failed relayOne power-off/power-on reset
c5Gear motor cautionThe gear motor locked, hunting, or overloaded mid-runLet the 30-minute auto-reset happen
c8Low ice production cautionIce production falling behind: refill intervals stretching past specCondenser and air filter
EbCondenser thermistor circuit openAn open circuit in the condenser thermistorOne power-off/power-on reset
EdOperation board communication errorLost communication between the operation (display) board and controller board for over a secondOne power-off/power-on reset
EEGear motor error (repeated)Five gear motor cautions (c5): the motor locked, hunting, or overloadedCheck the room isn't excessively hot and the machine has ventilation
EFAbnormal low voltage (repeated)Three low-voltage cautions (c3) within 24 hours — the building supply is repeatedly saggingWhat else runs on the same circuit
ELBin control switch errorIce jams or bridging in the bin and chute preventing normal dispensing countsStorage bin and dispensing chute for ice jams or bridging
EPModel setting number errorThe controller board's model number not set — almost always after a board was replaced without completing setupOne power-off/power-on reset
EUController board errorA failed IC on the controller board — an internal board failureOne power cycle (off, wait, on)
Supplies these steps call for
  • Hoshizaki water filter cartridges — Match the cartridge part number printed on your existing filter housing — cartridges are not interchangeable between systems.

Amazon links. As an Amazon Associate this site earns from qualifying purchases, at no extra cost to you.

E0: Icemaking water leak (interlock error)

The water-leak caution (c0) occurred twice in a row: the reservoir is losing water through the water circuit — reservoir, hoses, hose joints, mechanical seal, or flush water valve — or the float switch is faulty. The service call lamp blinks, E0 blinks, and the whole unit stops with dispensing disabled.

What's usually behind it (causes and parts most often involved):

  • A water leak in the icemaking circuit: reservoir, hoses, hose joints, the auger's mechanical seal, or the flush water valve
  • A faulty float switch misreporting water loss
  • The escalated form of two consecutive c0 water-leak cautions

The looking, yes: check for visible water under and inside the machine and at reachable hose connections, then one power-off/power-on reset. A visible drip is a finding worth photographing for the tech.

Diagnostic sequence — what to try, in order:

  1. Look for visible water leaking under or inside the machine
  2. Check hose connections you can see without disassembly
  3. Reset by turning the power supply off and back on

What to check before you call:

  • Water on the floor or inside the cabinet — E0 means water is leaving the circuit. A visible drip narrows the search a lot, so photograph it for the tech.
  • Reachable hose connections — Check the joints you can see without disassembly. Don't open the icemaking mechanism.
  • Whether c0 appeared before — E0 follows two consecutive c0 water-leak cautions, so earlier c0 entries confirm a real, repeating leak.
  • Result of one power-off/power-on reset — If E0 returns after one reset, stop and call. The cause is inside the water circuit or the float switch.

Parts a technician may look at (based on the causes listed for this code — a tech confirms first):

  • Hoses and hose joints
  • Auger mechanical seal
  • Flush water valve
  • Reservoir
  • Float switch

What might it cost? Can run into a moderate repair — a rough typical range, not a quote.

Why it needs a technician: Tracing a leak through the water circuit — especially the auger's mechanical seal — requires disassembly of the icemaking mechanism, and a failed mechanical seal is a significant dispenser repair that should be diagnosed precisely before parts are ordered.

When to call: If E0 returns after a power cycle, a technician needs to trace the leak in the water circuit or replace the float switch.

Source: HOS-DCM-KE_spm.pdf (partstown.com)

E1: Low ice production (interlock error)

The low-production caution (c8) occurred twice in a row — the interval between reservoir refills got too long, meaning the machine isn't making ice at the expected rate. Listed causes include a refrigerant gas leak, control water valve not closing, vapor lock, a freeze-up, or float switch / bin control switch faults. The unit stops and dispensing is disabled.

What's usually behind it (causes and parts most often involved):

  • A refrigerant gas leak
  • A control water valve not closing
  • Vapor lock or an internal freeze-up
  • Float switch or bin control switch faults
  • The escalated form of two consecutive c8 low-production cautions

The supporting checks: clean the condenser and air filter, confirm steady water, one power-cycle reset. E1's cause list is dominated by sealed-system and component failures, so set expectations accordingly.

Diagnostic sequence — what to try, in order:

  1. Check the condenser and air filter are clean and airflow is unobstructed
  2. Confirm the water supply is steady
  3. Reset by turning the power supply off and back on

What to check before you call:

  • Condenser and air filter — These are the supporting checks Hoshizaki's guidance lists. Clean them before calling, so the tech isn't billing you to do it.
  • Steady water supply — Confirm the valve is open and the filter isn't spent.
  • History of c8 cautions — E1 follows two consecutive c8 low-production cautions. Tell the tech how often c8 showed up before the lockout.
  • Result of one reset — Power off and back on once. If E1 returns, the remaining causes are mostly sealed-system and component faults.

Parts a technician may look at (based on the causes listed for this code — a tech confirms first):

  • Refrigeration circuit (leak detection and repair by an EPA-certified technician)
  • Control water valve
  • Float switch
  • Bin control switch

What might it cost? Can be a major repair — a rough typical range, not a quote.

Why it needs a technician: Gas leaks and vapor lock are refrigeration diagnoses — gauges, leak detection, EPA-certified repair. The dispenser locked itself out because production genuinely collapsed twice in a row; that persistence is why this one rarely ends without a service visit.

When to call: If E1 recurs, refrigeration diagnosis (possible gas leak or vapor lock) requires a certified technician.

Source: HOS-DCM-KE_spm.pdf (partstown.com)

c1: Low water caution

Water supply ran more than 90 seconds, or the float switch stayed at the low level more than 60 seconds after filling — the machine isn't getting water. The icemaking lamp blinks and the unit pauses; it automatically resets once the reservoir fills.

What's usually behind it (causes and parts most often involved):

  • The water supply valve closed or restricted
  • A kinked line or clogged filter
  • A control water valve or float switch fault if supply is verified

Usually — open the valve fully, check the filter and line, and the caution resets itself once the reservoir fills. Water delivery is the whole story most times.

Diagnostic sequence — what to try, in order:

  1. Open the water supply shut-off valve fully
  2. Check for a kinked line or clogged water filter
  3. Wait for the automatic reset once water flows again

What to check before you call:

  • Shut-off valve fully open — c1 fires when the water fill runs over 90 seconds or the float stays low for 60 seconds after filling, so a half-closed valve is enough to trigger it.
  • Water filter cartridge — A spent or clogged filter starves the fill; if the cartridge is past its change interval, replace it before anything else.
  • Supply line behind the unit — Look for a kink or crushed line where the machine was pushed back against the wall.
  • Whether other fixtures on the line lost pressure — If a nearby sink or machine is also weak, the problem is the building supply, not the dispenser.
  • How often c1 repeats — A one-off after a water shutoff is nothing. Repeated c1 with good water points at the control water valve or float switch.

Parts a technician may look at (based on the causes listed for this code — a tech confirms first):

  • Water filter cartridge (customer-replaceable on most installs)
  • Control water valve
  • Float switch

What might it cost? Usually little or no parts cost — a rough typical range, not a quote.

Why it needs a technician: Verified water with continuing c1 cautions means the control water valve or float switch is failing — component testing, and worth doing before the caution pattern escalates into a lockout error.

When to call: If water supply is confirmed and c1 continues, the control water valve or float switch needs service.

Source: HOS-DCM-KE_spm.pdf (partstown.com)

E2: Float switch error

With the flush water valve off, the float switch reported tripped at both the upper and lower float levels simultaneously for 2 seconds — an impossible state, indicating a faulty float switch. The unit stops and dispensing is disabled.

What's usually behind it (causes and parts most often involved):

  • A float switch reporting an impossible state (tripped at both levels simultaneously)
  • Scale or debris fouling the float mechanism
  • A failed float switch

One power-cycle, and (power off first) a check that the float switch connector is seated. The impossible-reading signature usually means the switch itself.

Diagnostic sequence — what to try, in order:

  1. Reset by turning the power supply off and back on
  2. If comfortable, check the float switch connector is seated (power off first)

What to check before you call:

  • One power-off/power-on reset — Rules out a one-time glitch.
  • Float switch connector (power off first) — If you're comfortable and the connector is reachable, check that it's fully seated.
  • Scale in the water circuit — Mineral scale or debris can foul the float. If the machine is overdue for cleaning, mention that to the tech.

Parts a technician may look at (based on the causes listed for this code — a tech confirms first):

  • Float switch (clean or replace)
  • Float switch connector or wiring

What might it cost? Typically a service call plus a modest part — a rough typical range, not a quote.

Why it needs a technician: A recurring E2 means the float switch needs cleaning or replacement done properly inside the water circuit — a small job, but one where correct reassembly matters for everything downstream of that sensor.

When to call: A recurring E2 means the float switch itself needs cleaning or replacement by a technician.

Source: HOS-DCM-KE_spm.pdf (partstown.com)

c2: Abnormal high-side pressure caution

The condenser thermistor read above its set point for 5 seconds — the condenser is running too hot. The icemaking lamp blinks and the unit stops, auto-resetting when the condenser cools back below the set point.

What's usually behind it (causes and parts most often involved):

  • The condenser running hot: dirty coil, dirty filter, blocked clearance
  • Poor ventilation or a hot room
  • Early fan motor or refrigeration problems

Yes, and now is the cheap moment: clean the filter and condenser, restore ventilation, let it cool and auto-reset. c2 is the warning; E4 is the lockout it becomes at five-in-an-hour.

Diagnostic sequence — what to try, in order:

  1. Clean the air filter and condenser
  2. Improve ventilation and clearance around the unit
  3. Let it cool and auto-reset, then monitor

What to check before you call:

  • Air filter — A clogged filter is the most common reason the condenser runs hot; cleaning it is a staff job.
  • Condenser coil — Dust and grease on the coil trap heat. Clean it per the manual with power off.
  • Clearance around the unit — Boxes, walls, or other equipment blocking the vents keep hot air recirculating.
  • Room temperature and nearby heat sources — Ovens, fryers, or a hot back room raise the condenser temperature the thermistor reads.
  • How many times c2 has appeared in the last hour — Five c2 cautions within one hour of compressor running escalates to an E4 lockout. Catch it before that.

Parts a technician may look at (based on the causes listed for this code — a tech confirms first):

  • Condenser fan motor
  • Condenser thermistor (if readings are suspect)
  • Refrigeration circuit components (technician diagnosis)

What might it cost? Typically a service call plus a modest part — a rough typical range, not a quote.

Why it needs a technician: Recurring c2 after a real cleaning points at the fan motor or refrigeration circuit. Catching it at the caution stage — before the E4 lockout — is the difference between a scheduled visit and an emergency one.

When to call: If c2 keeps recurring (5 in an hour escalates to an E4 lockout), have a technician check the fan motor and refrigeration circuit.

Source: HOS-DCM-KE_spm.pdf (partstown.com)

E3: Gear motor error (protective circuit)

The gear motor relay is on but the gear motor's protective circuit detector reports off — the thermal protector or overload in the gear motor circuit has opened, or the relay is faulty. The unit stops and dispensing is disabled.

What's usually behind it (causes and parts most often involved):

  • The gear motor's thermal protector or overload opening under load
  • A locked or straining auger
  • A faulty gear motor relay

The cooldown: leave it powered off 30+ minutes so an overheated protector can reset, then one power-cycle. If it comes straight back, stop.

Diagnostic sequence — what to try, in order:

  1. Let the machine sit powered off for 30+ minutes so an overheated motor protector can cool
  2. Reset by turning the power supply off and back on

What to check before you call:

  • Leave the machine powered off for 30+ minutes — Hoshizaki's listed first step for E3. An overheated gear motor thermal protector needs time to cool and reset.
  • One power-off/power-on reset — After the cooldown, turn the power supply off and back on once to clear the lockout.
  • If E3 comes straight back, stop — A gear motor that keeps tripping its protection is either binding mechanically or failing electrically. Forcing restarts against a straining auger can turn a motor repair into a gearbox rebuild.
  • Note whether c-codes or other E-codes appeared first — On the DCM, lowercase c-codes are cautions and uppercase E-codes are lockouts. Telling the technician exactly what showed, and in what order, helps the diagnosis.

Parts a technician may look at (based on the causes listed for this code — a tech confirms first):

  • Gear motor (thermal protector or overload)
  • Auger (if locked or straining)
  • Gear motor relay

What might it cost? Can run into a moderate repair — a rough typical range, not a quote.

Why it needs a technician: A gear motor that keeps tripping its protection is either binding mechanically or failing electrically — and the auger drive is the heart of a cubelet dispenser. Forcing restarts against a straining auger converts a motor repair into a gearbox rebuild.

When to call: If E3 comes back, the gear motor protective circuit and relay need professional testing.

Source: HOS-DCM-KE_spm.pdf (partstown.com)

c3: Abnormal low voltage caution

Supply voltage stayed below the setting for more than 1 second (ignored for the first 15 seconds after compressor start). The unit stops and automatically resets after voltage stays above the reset setting for 2 minutes.

What's usually behind it (causes and parts most often involved):

  • Supply voltage sagging below the setting for over a second
  • Circuit loading: big equipment starting on the same supply

Observation and patience — it auto-resets after two minutes of stable voltage. Note the timing pattern; that's the diagnosis.

Diagnostic sequence — what to try, in order:

  1. Check for overloaded circuits or big loads starting on the same supply
  2. Wait for the automatic reset

What to check before you call:

  • What else is on the same circuit — Large equipment starting on the same supply can pull voltage below the setting for more than a second.
  • When c3 happens — Write down the time of each event. A pattern that lines up with another machine starting is the diagnosis an electrician needs.
  • Extension cords or adapters — The dispenser should be on its proper dedicated supply. Temporary wiring can cause voltage sag.
  • Count of c3 events in 24 hours — Three c3 events in 24 hours locks the machine out with EF, so the second one is the time to call.

Parts a technician may look at (based on the causes listed for this code — a tech confirms first):

  • Usually no ice-machine part, since the cause is the building's electrical supply
  • Wiring or circuit work by a licensed electrician

What might it cost? Typically a service call plus a modest part — a rough typical range, not a quote.

Why it needs a technician: Three c3 events in 24 hours locks the machine out with EF, so the time to get an electrician measuring the circuit is at the first repeat, not after the lockout.

When to call: Three c3 events in 24 hours locks the machine out with EF — get an electrician before that point.

Source: HOS-DCM-KE_spm.pdf (partstown.com)

E4: Abnormal high-side pressure

The high-pressure caution (c2) occurred 5 times within 1 hour of compressor operation. Listed causes: fan motor failure, refrigeration circuit problems, clogged condenser, or poor installation conditions (heat, no airflow). E4 blinks on the display.

What's usually behind it (causes and parts most often involved):

  • Five high-pressure cautions (c2) within one hour of compressor running
  • A clogged condenser or dead fan motor
  • Poor installation: heat, no clearance, no airflow
  • Refrigeration circuit problems

The airflow tier, thoroughly: clean the condenser and filter, restore clearance and ventilation, confirm the fan spins with the compressor (look and listen, don't touch). Then one reset.

Diagnostic sequence — what to try, in order:

  1. Clean the condenser and air filter
  2. Give the machine clearance and ventilation; move heat sources away
  3. Confirm the condenser fan spins when the compressor runs (listen/look, don't touch)

Why it needs a technician: Five pressure events in an hour is a sustained pattern, not a fluke. If cleaning doesn't break it, the fan motor or refrigeration circuit needs instrument diagnosis — pressure problems ignored at the caution stage arrive here, and pushed further they arrive at the compressor.

When to call: If cleaning and airflow don't fix it, a technician must check the fan motor and refrigeration circuit.

Source: HOS-DCM-KE_spm.pdf (partstown.com)

E5: Gear motor drive element error

The gear motor relay is off but the protective circuit detector reads on — Hoshizaki lists miswiring or a failed gear motor relay, and the fix is typically controller board replacement. The unit stops and dispensing is disabled.

What's usually behind it (causes and parts most often involved):

  • The gear motor relay reading on when commanded off — miswiring or a failed relay
  • A controller board fault (Hoshizaki's documented fix is typically board replacement)

One power-cycle reset; if it returns, leave the machine off. There is no user-serviceable version of a drive-element fault.

Diagnostic sequence — what to try, in order:

  1. Reset once by turning the power supply off and back on
  2. If it returns, leave the machine off

What to check before you call:

  • One power-off/power-on reset — Hoshizaki's listed first step for E5. It rules out a one-time glitch.
  • If E5 returns, leave the machine off — There is no user-serviceable version of a drive-element fault. Running a board that misdrives the gear motor relay risks the drive system it's failing to control.
  • Write down the model and serial number — The documented fix is typically controller board replacement, and a new board has to be set to your exact model.
  • Ask the technician to finish the model-code setup — If a replacement board's model number isn't set, the machine shows EP and stays stopped.

Parts a technician may look at (based on the causes listed for this code — a tech confirms first):

  • Controller board (replacement plus model-code setup)
  • Gear motor relay
  • Wiring between the board and gear motor circuit (miswiring check)

What might it cost? Can run into a moderate repair — a rough typical range, not a quote.

Why it needs a technician: The documented remedy is controller board replacement — a precise, panel-open repair. A board misdriving the gear motor relay can't be worked around safely, and running it risks the drive system it's failing to control.

When to call: E5 that recurs means the controller board likely needs replacement — call a technician.

Source: HOS-DCM-KE_spm.pdf (partstown.com)

c5: Gear motor caution

While the gear motor was running, its voltage detection signal dropped out — the motor is locked, hunting, or overloaded, or supply voltage / high ambient temperature is the cause. The unit stops and automatically resets after 30 minutes.

What's usually behind it (causes and parts most often involved):

  • The gear motor locked, hunting, or overloaded mid-run
  • Heat or supply voltage stressing the drive
  • Early auger-system wear

The environment and the wait: reduce room heat, improve ventilation, and let the 30-minute auto-reset do its job. Do not attempt to free the auger yourself.

Diagnostic sequence — what to try, in order:

  1. Let the unit sit — it auto-resets after 30 minutes
  2. Reduce room heat and improve ventilation
  3. Do not attempt to free the auger yourself

What to check before you call:

  • Let the 30-minute auto-reset happen — c5 resets itself after 30 minutes. Interrupting it with repeated power cycles doesn't help the motor.
  • Room heat and ventilation — High ambient temperature is a listed cause. Bring the room temperature down and clear the vents.
  • Supply voltage issues — Low or unstable voltage is also listed. If you've seen c3 cautions too, mention it to the technician.
  • Unusual noise from the auger area — Grinding, clicking, or straining sounds are worth noting for the tech. Don't try to free the auger yourself.

Parts a technician may look at (based on the causes listed for this code — a tech confirms first):

  • Gear motor
  • Auger and auger bearings
  • Gear motor relay or protective circuit (technician testing)

What might it cost? Can run into a moderate repair — a rough typical range, not a quote.

Why it needs a technician: The auger drive is precision machinery; a motor that drops out under load needs mechanical and electrical inspection. Five c5 events become an EE lockout — a second occurrence is your booking signal.

When to call: Five c5 events escalate to an EE lockout; if you see c5 more than once, book a service call.

Source: HOS-DCM-KE_spm.pdf (partstown.com)

c8: Low ice production caution

The interval between reservoir refills exceeded the limit (DCM-60KE: 40 min first cycle / 20 min after; DCM-120KE: 30 min / 15 min) — the machine isn't consuming water at the expected icemaking rate. The unit stops then automatically restarts; it's recorded in the error log.

What's usually behind it (causes and parts most often involved):

  • Ice production falling behind: refill intervals stretching past spec
  • A dirty condenser or air filter
  • Water leaks bleeding the reservoir
  • Early refrigeration decline

The maintenance tier: clean the condenser and filter, look for water leaks around the reservoir and hoses, and watch whether the caution recurs after the automatic restart.

Diagnostic sequence — what to try, in order:

  1. Clean the condenser and air filter
  2. Check for water leaks around the reservoir and hoses
  3. Watch whether the caution recurs after the automatic restart

What to check before you call:

  • Condenser and air filter — A dirty condenser slows ice production and stretches refill intervals. Clean both first.
  • Leaks around the reservoir and hoses — Water leaking out of the circuit also throws off the refill timing c8 watches.
  • Whether c8 recurs after the automatic restart — The unit restarts on its own. One c8 is a warning; two in a row lock it out with E1.
  • Your model's limits — The refill-interval limits differ: DCM-60KE is 40 minutes on the first cycle and 20 after; DCM-120KE is 30 and 15. That's why the two models can flag at different times.

Parts a technician may look at (based on the causes listed for this code — a tech confirms first):

  • Air filter (cleanable)
  • Hoses and hose joints (if a leak is found)
  • Refrigeration components if a gas leak or vapor lock is diagnosed

What might it cost? Can run into a moderate repair — a rough typical range, not a quote.

Why it needs a technician: Two consecutive c8 events lock the machine out with E1 — and the deeper causes (gas leak, vapor lock) are refrigeration diagnoses. A recurring c8 is the early, cheap version of that service call; take it.

When to call: Two consecutive c8 events lock the machine out with E1 — recurring c8 means call for refrigeration diagnosis.

Source: HOS-DCM-KE_spm.pdf (partstown.com)

Eb: Condenser thermistor circuit open

The condenser thermistor circuit is open, so the board cannot read condenser temperature. The service call lamp blinks and the unit stops with dispensing disabled.

What's usually behind it (causes and parts most often involved):

  • An open circuit in the condenser thermistor
  • A damaged sensor wire or failed thermistor

One power-cycle to rule out a transient. That's the scope — the sensor lives in the refrigeration section.

Diagnostic sequence — what to try, in order:

  1. Reset by turning the power supply off and back on

What to check before you call:

  • One power-off/power-on reset — Hoshizaki's listed first step for Eb. It rules out a one-time glitch in the reading.
  • Whether Eb returns after the reset — An open thermistor circuit doesn't fix itself. If Eb comes back, the sensor or its wiring has failed, and further resets won't change that.
  • Recent work or moves near the refrigeration section — A damaged sensor wire is one of the listed causes. If the unit was recently serviced, moved, or pushed back against a wall, tell the technician.
  • Leave the panels closed — The condenser thermistor sits in the refrigeration section. Testing it is a resistance measurement for a technician, not an owner check.

Parts a technician may look at (based on the causes listed for this code — a tech confirms first):

  • Condenser thermistor
  • Thermistor wiring or connector

What might it cost? Typically a service call plus a modest part — a rough typical range, not a quote.

Why it needs a technician: Without its condenser thermistor the board can't watch head pressure's proxy, so it stops. Replacement is a component swap a technician confirms with a resistance test first.

When to call: If Eb returns, the condenser thermistor needs professional replacement.

Source: HOS-DCM-KE_spm.pdf (partstown.com)

Ed: Operation board communication error

The operation (display) board failed to communicate with the controller board for more than 1 second. Causes: controller board, operation board, or the communication line between them. The unit stops and dispensing is disabled.

What's usually behind it (causes and parts most often involved):

  • Lost communication between the operation (display) board and controller board for over a second
  • A failing communication line between them
  • A failing board on either end

One power-cycle. Communication hiccups occasionally clear for good; a recurring Ed doesn't.

Diagnostic sequence — what to try, in order:

  1. Reset by turning the power supply off and back on

What to check before you call:

  • One power-off/power-on reset — Hoshizaki's listed first step for Ed. Communication hiccups occasionally clear for good.
  • Whether Ed returns after the reset — A recurring Ed doesn't clear itself. If it comes back, the communication line or a board on either end has failed.
  • Leave the machine off if Ed returns — Ed stops the unit and disables dispensing. Recurring Ed errors require a technician to check the boards and the ribbon/communication cable.
  • Don't swap boards on a guess — The listed causes are the operation (display) board, the controller board, or the cable between them. Sequential testing of each end and the cable avoids replacing the wrong board.

Parts a technician may look at (based on the causes listed for this code — a tech confirms first):

  • Operation (display) board
  • Controller board
  • Ribbon/communication cable between the boards

What might it cost? Can run into a moderate repair — a rough typical range, not a quote.

Why it needs a technician: Board-to-board communication faults are isolated by testing each end and the cable between — sequential diagnosis with the panel open, where swapping the wrong board is the expensive path an hour of proper testing avoids.

When to call: Recurring Ed errors require a technician to check the boards and the ribbon/communication cable.

Source: HOS-DCM-KE_spm.pdf (partstown.com)

EE: Gear motor error (repeated)

The gear motor caution (c5) occurred 5 times — the gear motor is locked, hunting, or overloaded, or supply voltage / high ambient temperature is stressing it. The unit stops and dispensing is disabled.

What's usually behind it (causes and parts most often involved):

  • Five gear motor cautions (c5): the motor locked, hunting, or overloaded
  • Ice jammed in the auger mechanism
  • Supply voltage or high ambient temperature stressing the drive

The environment: reduce room heat, improve ventilation, one power-cycle. If ice is jammed in the mechanism, note it and do not force it — that observation is exactly what the tech needs.

Diagnostic sequence — what to try, in order:

  1. Check the room isn't excessively hot and the machine has ventilation
  2. Reset by turning the power supply off and back on
  3. If ice is jammed in the mechanism, do not force it — note it for the technician

Why it needs a technician: A locked or overloaded auger motor means opening the drive system — and prying at a jammed auger without disassembly knowledge damages the very parts (bearings, seals, gearbox) that make dispenser repairs expensive. Five strikes in the log says this is past coincidence.

When to call: A locked or overloaded auger gear motor needs professional service; repeated EE errors mean stop and call.

Source: HOS-DCM-KE_spm.pdf (partstown.com)

EF: Abnormal low voltage (repeated)

The low-voltage caution (c3) occurred 3 times in 24 hours — supply voltage repeatedly dropped below the setting. The unit stops and dispensing is disabled until power is cycled.

What's usually behind it (causes and parts most often involved):

  • Three low-voltage cautions (c3) within 24 hours — the building supply is repeatedly sagging
  • Shared or overloaded circuits
  • Heavy equipment starting on the same supply

The log and the reset: note when it happens and what else runs then, power-cycle to restore operation. The dispenser is reporting a building problem.

Diagnostic sequence — what to try, in order:

  1. Check for shared/overloaded circuits or heavy equipment starting on the same supply
  2. Reset by turning the power supply off and back on

What to check before you call:

  • What else runs on the same circuit — Shared or overloaded circuits and heavy equipment starting on the same supply are the listed causes. Note what was running each time.
  • When the c3 cautions happened — EF follows three low-voltage cautions (c3) within 24 hours. The timing pattern is what an electrician needs to find the cause.
  • One power-off/power-on reset — EF stops the unit until power is cycled. The reset restores operation, but it doesn't fix the building supply.
  • Call an electrician if EF repeats — Three sags in a day is a building electrical pattern. Measuring the circuit under load and correcting the supply is electrician work.

Parts a technician may look at (based on the causes listed for this code — a tech confirms first):

  • Usually no ice-machine part, since the cause is the building's electrical supply
  • Wiring or circuit work by a licensed electrician

What might it cost? Typically a service call plus a modest part — a rough typical range, not a quote.

Why it needs a technician: Three sags in a day is a pattern for an electrician — measuring the circuit under load and correcting the supply. Ignoring it costs motor and board life across everything on that circuit.

When to call: Repeated EF errors are a building electrical supply problem — call an electrician.

Source: HOS-DCM-KE_spm.pdf (partstown.com)

EL: Bin control switch error

While the compressor was running, the number of consecutive reservoir water-supply cycles hit the limit (12 on DCM-60KE, 24 on DCM-120KE) without ice being dispensed or the compressor stopping — the board suspects the bin control switch isn't detecting a full bin. The unit stops and dispensing is disabled.

What's usually behind it (causes and parts most often involved):

  • Ice jams or bridging in the bin and chute preventing normal dispensing counts
  • A bin control switch failing to detect a full bin
  • The water-supply-cycle limit tripping as the symptom of either

The clearing, yes: check the storage bin and dispensing chute for jams and bridging, break up what you find (in the bin, not the mechanism), and power-cycle.

Diagnostic sequence — what to try, in order:

  1. Check the storage bin and dispensing chute for ice jams or bridging
  2. Reset by turning the power supply off and back on

What to check before you call:

  • Storage bin and dispensing chute for ice jams or bridging — Hoshizaki's listed first step for EL. Jammed or bridged ice keeps normal dispensing from happening, which is how the water-supply-cycle limit gets reached.
  • Break up what you find in the bin, not in the mechanism — Clearing the bin and chute is the owner-level fix. Leave the auger and drive alone; that is technician territory on a cubelet dispenser.
  • One power-off/power-on reset — EL is an interlock error: the unit stops and dispensing is disabled until the power supply is turned off and back on.
  • Whether EL returns with a clear bin — With a clear bin and chute, a returning EL means the bin control switch itself has failed. Replacement needs a powered test to confirm the new switch actually reads the bin.
  • Your model's limit — The board counts consecutive reservoir water-supply cycles while the compressor runs: 12 on the DCM-60KE, 24 on the DCM-120KE. That's why the two models can trip EL at different points.

Parts a technician may look at (based on the causes listed for this code — a tech confirms first):

  • Bin control switch
  • Nothing, if the cause was an ice jam or bridging in the bin or chute

What might it cost? Typically a service call plus a modest part — a rough typical range, not a quote.

Why it needs a technician: With a clear bin and chute, a returning EL means the bin control switch itself has failed — replacement with proper verification that the new switch actually reads the bin, which is a powered test.

When to call: If EL returns with a clear bin, the bin control switch needs professional replacement.

Source: HOS-DCM-KE_spm.pdf (partstown.com)

EP: Model setting number error

The controller board's model number is not set — usually after a board replacement done incorrectly. The unit stops and dispensing is disabled.

What's usually behind it (causes and parts most often involved):

  • The controller board's model number not set — almost always after a board was replaced without completing setup

A power-cycle is worth one try, but this code exists because a service procedure was left unfinished — the fix is completing it, not resetting around it.

Diagnostic sequence — what to try, in order:

  1. Reset by turning the power supply off and back on

What to check before you call:

  • One power-off/power-on reset — Hoshizaki's only listed owner step for EP. It's worth one try, but this code means a service procedure was left unfinished, so a reset rarely clears it.
  • Whether the controller board was recently replaced — EP almost always appears after a board replacement where the model number wasn't set. If the unit was just serviced, that visit is the place to start.
  • Call the technician who installed the board — Setting the board's model code is part of the service procedure. Finishing the job is the installer's responsibility.
  • Don't try to set the model code yourself — It needs the service procedure and the correct code for your exact model. A wrong setting runs the machine with the wrong parameters.

Parts a technician may look at (based on the causes listed for this code — a tech confirms first):

  • Usually no new part, since the board is already installed
  • Controller board model-code setup (service procedure)

What might it cost? Typically a service call plus a modest part — a rough typical range, not a quote.

Why it needs a technician: Setting the board's model code requires the service procedure and correct code for your exact model; a wrong setting runs the machine with wrong parameters. Call whoever installed the board — finishing the job is theirs.

When to call: Setting the board's model code is a service procedure — call the technician who installed the board.

Source: HOS-DCM-KE_spm.pdf (partstown.com)

EU: Controller board error

The controller board's IC has failed. Hoshizaki's remedy is controller board replacement. The unit stops and dispensing is disabled.

What's usually behind it (causes and parts most often involved):

  • A failed IC on the controller board — an internal board failure

One power-cycle, then leave it off if EU returns. There's nothing to adjust or clean; the board's brain has failed.

Diagnostic sequence — what to try, in order:

  1. Try one power cycle (off, wait, on)
  2. If EU returns, leave the machine off

What to check before you call:

  • One power cycle (off, wait, on) — Rules out a one-time glitch before you book service.
  • If EU returns, leave it off — EU means the controller board's IC has failed. A board in that state can't be trusted to run the machine's safeties.
  • Write down the model and serial number — A replacement controller board has to be set to your exact model. Having the numbers ready speeds up the parts order.
  • Ask the technician to finish the model-code setup — If the new board's model number isn't set, the machine shows EP and stays stopped.

Parts a technician may look at (based on the causes listed for this code — a tech confirms first):

  • Controller board (replacement plus model-code setup)

What might it cost? Can run into a moderate repair — a rough typical range, not a quote.

Why it needs a technician: Hoshizaki's remedy is board replacement, full stop. A controller with a failed IC can't be trusted to run safeties, and the swap plus model-code setup is a service procedure end to end.

When to call: EU means the controller board needs replacing — call for service.

Source: HOS-DCM-KE_spm.pdf (partstown.com)

Related questions

How do I find my Hoshizaki DCM-60KE / DCM-120KE cubelet dispenser code in this list?

Your machine shows one of 18 documented codes or signals. Use the table above — click your code to jump straight to its section.

Can I fix a Hoshizaki DCM-60KE / DCM-120KE cubelet dispenser code myself?

Many of these 18 codes trace back to scale, dirty coolers, or a water-supply problem that in-house staff can address — each section above gives the documented first steps. Anything the page flags as refrigerant, compressor, or electrical-cabinet related needs a certified technician.

When does a Hoshizaki DCM-60KE / DCM-120KE cubelet dispenser code need a technician?

Any code whose causes reach the sealed refrigeration system, the compressor, or the electrical cabinet needs a technician — those repairs require EPA Section 608 certification and diagnostic tooling most kitchens don't have. Each code section above says which side of that line it falls on.

What's the difference between a c-code and an E-code on a Hoshizaki DCM-60KE or DCM-120KE?

Lowercase c-codes are cautions: the machine pauses or adjusts and usually resets itself once the condition clears. Uppercase E-codes are interlock errors: the unit has stopped, dispensing is disabled, and most need a power-off/power-on reset after the cause is fixed. Cautions escalate into errors when they repeat — two c8 low-production cautions become an E1 lockout, and five c2 pressure cautions become an E4 — so a caution is the cheaper moment to act.

Manufacturer source(s) verified for this page: HOS-DCM-KE_spm.pdf (partstown.com)

This page covers ice-making specifics only — the harvest cycle, water systems, and ice quality. For how a compressor works in general, see aircompressorcodes.com. For refrigeration-cycle and condenser fundamentals, see walkincoolercodes.com.

Equipment still down? If you're in Middle Tennessee or Central Alabama, see who services commercial ice machines near you:
Nashville, TN →  ·  Birmingham, AL →